1t/H Fuel Wide Applicability Strong Vertical Multi-Fuel Steam Boiler

Product Details
Customization: Available
Function: Steam Boilers
Fuel: Gas-Fired
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Self-branded
The supplier has 1 Self-brands, check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (11)
  • 1t/H Fuel Wide Applicability Strong Vertical Multi-Fuel Steam Boiler
  • 1t/H Fuel Wide Applicability Strong Vertical Multi-Fuel Steam Boiler
  • 1t/H Fuel Wide Applicability Strong Vertical Multi-Fuel Steam Boiler
  • 1t/H Fuel Wide Applicability Strong Vertical Multi-Fuel Steam Boiler
  • 1t/H Fuel Wide Applicability Strong Vertical Multi-Fuel Steam Boiler
  • 1t/H Fuel Wide Applicability Strong Vertical Multi-Fuel Steam Boiler
Find Similar Products
  • Overview
  • Product Description
  • FAQ
Overview

Basic Info.

Model NO.
LN-1T Vertical Steam
Installation
Assembled Boiler
Structure
Fire Tube
Media
Steam and Water
Water Circulation
Natural Circulation
Drum Placement
Horizontal Boiler
Pressure
Low Pressure
Manufacturing Level
A
Burning Style
Chamber Combustion Boiler
Usage
Industrial, Home, Vehicle, Power Station
Team Production
100kw to 2800kw
Warranty Period
1 Year
Core Selling Point
Long Service Life
Types
Natural Circulation Boilers
Rated Thermal Power
350kw, 0.35MW
Rated Output/Water Temperature
85/60 C
Core Component
Boiler Body
Burner Model
Tbg60,Italy
Style
Vertical
Hot Water Circulation Pump
Td50-38/2
Transport Package
Wooden Case
Specification
Vertical-1T steam
Trademark
LN
Origin
China
HS Code
8404101000
Production Capacity
1000kg/H

Packaging & Delivery

Package Size
130.00cm * 120.00cm * 215.00cm
Package Gross Weight
1000.000kg

Product Description

Product Description

Vertical steam multi-fuel boiler, using advanced design concept and manufacturing process, made in China, with its high efficiency, environmental protection, multi-fuel adaptability, widely used in all walks of life. The vertical structure of the boiler, small footprint, easy installation and maintenance, is the ideal choice for small and medium-sized enterprises and factory.1t/H Fuel Wide Applicability Strong Vertical Multi-Fuel Steam Boiler

 
 
 
Model
 
Rated capacity
Water temperature
          Back
Water temperature
Oil consumption
Weight of main parts
megawatt
ºC
ºC
Natural gas
Diesel oil

Liquefied petroleum gas
Ton
CLHS0.10-85/60-Y(Q)
0.10
85
60
12
9.5
5
0.96
SLHS0.15-85/60-Y(Q)
0.15
85
60
13.3
10.8
7
1.0
CLHS0.21-85/60-Y(Q)
0.21
85
60
25.5
19.2
9.3
1.2
CLHS0.35-85/60-Y(Q)
0.35
85
60
41.5
34.3
15
1.7
LHS0.49-0.4/95/60-Y(Q)
0.49
95
70
64.5
49.5
22
2
LHS0.7-0.4/95/70-Y(Q)
0.7
95
70
84
65
28
2.6
 1t/H Fuel Wide Applicability Strong Vertical Multi-Fuel Steam Boiler1t/H Fuel Wide Applicability Strong Vertical Multi-Fuel Steam Boiler1t/H Fuel Wide Applicability Strong Vertical Multi-Fuel Steam Boiler1t/H Fuel Wide Applicability Strong Vertical Multi-Fuel Steam Boiler1t/H Fuel Wide Applicability Strong Vertical Multi-Fuel Steam Boiler1t/H Fuel Wide Applicability Strong Vertical Multi-Fuel Steam Boiler1t/H Fuel Wide Applicability Strong Vertical Multi-Fuel Steam Boiler
FAQ
1.Q: What are the main features of WNS series boilers?

A: WNS series boiler adopts horizontal internal combustion three-return structure, which has the characteristics of high efficiency, energy saving, environmental protection effect, high degree of automation and safety and reliability. High combustion efficiency, low heat loss, low flue gas emission concentration, and equipped with advanced computer control system and a variety of safety protection devices.

2.Q: What is the working pressure and capacity range of the boiler?

A: WNS series boilers have a working pressure range of 0.7-1.6MPa and a capacity ranging from 0.3 tons to 20 tons, suitable for a variety of industrial applications.

3.Q: What is the insulation material of the boiler?

A: The boiler uses centrifugal glass wool as insulation material, which has good insulation performance, lightweight and low heat loss.

4.Q: What safety matters should be paid attention to when the boiler is running?

A: Keep the water level within the normal range during boiler operation to avoid low water level operation; Regularly check the boiler safety valve, pressure gauge and other safety accessories are working properly; Pay attention to the combustion of the boiler and avoid overpressure operation.

5.Q: How is the boiler maintained on a daily basis?

A: The daily maintenance of the boiler includes regular inspection of the boiler body, electrical equipment, feed water pump, various valves, meters and auxiliary equipment, etc. Any abnormal situation should be handled in time and recorded. At the same time, water quality treatment should be carried out in accordance with relevant specifications to ensure that the water quality of the boiler meets the requirements.

6.Q: How to test the energy efficiency of boilers?

A: The boiler user shall conduct energy efficiency testing every two years, which shall be carried out in conjunction with the external inspection of the boiler and shall be carried out by an institution with appropriate qualifications. The test content includes the fuel consumption of the boiler, the outlet temperature and pressure of the medium, the boiler water supply and the feed water temperature and other key indicators.

7.Q: What should I do if the boiler has a low water level alarm?

A: When the boiler has a low water level alarm, the water level of the boiler should be checked immediately to confirm whether there is a lack of water. If there is a lack of water, water should be quickly replenished to the normal water level, and check the cause of the water shortage to prevent recurrence.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now