Customizable Gas-Fired Steam Boiler Solutions in China From Ln

Product Details
Customization: Available
Function: Steam Boilers
Fuel: Gas-Fired

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Self-branded
The supplier has 1 Self-brands, check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (11)
  • Customizable Gas-Fired Steam Boiler Solutions in China From Ln
  • Customizable Gas-Fired Steam Boiler Solutions in China From Ln
  • Customizable Gas-Fired Steam Boiler Solutions in China From Ln
  • Customizable Gas-Fired Steam Boiler Solutions in China From Ln
  • Customizable Gas-Fired Steam Boiler Solutions in China From Ln
  • Customizable Gas-Fired Steam Boiler Solutions in China From Ln
Find Similar Products

Basic Info.

Model NO.
WNS0.4-1.25-Y(Q)
Installation
Assembled Boiler
Structure
Fire Tube
Media
Steam
Water Circulation
Natural Circulation
Drum Placement
Horizontal Boiler
Pressure
Low Pressure
Manufacturing Level
A
Burning Style
Chamber Combustion Boiler
Usage
Industrial
Transport Package
Wooden Case
Specification
0.4T Gas-fired steam boiler
Trademark
LN
Origin
China
HS Code
8404101000
Production Capacity
400kg/H

Product Description

The customizable 0.4 T vertical gas steam boiler solutions boast versatile functionality. They efficiently convert gas energy into high-quality steam, with a rated evaporation capacity of 0.4 tons per hour, meeting the steam demands of small to medium-sized industrial processes, such as food processing, textile manufacturing, and chemical production. The vertical design saves installation space, while the customizable features allow for adjustments in pressure, temperature, and auxiliary components to adapt to specific operational requirements, ensuring optimal performance and energy efficiency.
Customizable Gas-Fired Steam Boiler Solutions in China From LnCustomizable Gas-Fired Steam Boiler Solutions in China From LnCustomizable Gas-Fired Steam Boiler Solutions in China From LnCustomizable Gas-Fired Steam Boiler Solutions in China From Ln

Customizable Gas-Fired Steam Boiler Solutions in China From Ln

Applicable Fuel
Light Oil\
1.Q: What are the main features of WNS series boilers?

A: WNS series boiler adopts horizontal internal combustion three-return structure, which has the characteristics of high efficiency, energy saving, environmental protection effect, high degree of automation and safety and reliability. High combustion efficiency, low heat loss, low flue gas emission concentration, and equipped with advanced computer control system and a variety of safety protection devices.

2.Q: What is the working pressure and capacity range of the boiler?

A: WNS series boilers have a working pressure range of 0.7-1.6MPa and a capacity ranging from 0.3 tons to 20 tons, suitable for a variety of industrial applications.

3.Q: What is the insulation material of the boiler?

A: The boiler uses centrifugal glass wool as insulation material, which has good insulation performance, lightweight and low heat loss.

4.Q: What safety matters should be paid attention to when the boiler is running?

A: Keep the water level within the normal range during boiler operation to avoid low water level operation; Regularly check the boiler safety valve, pressure gauge and other safety accessories are working properly; Pay attention to the combustion of the boiler and avoid overpressure operation.

5.Q: How is the boiler maintained on a daily basis?

A: The daily maintenance of the boiler includes regular inspection of the boiler body, electrical equipment, feed water pump, various valves, meters and auxiliary equipment, etc. Any abnormal situation should be handled in time and recorded. At the same time, water quality treatment should be carried out in accordance with relevant specifications to ensure that the water quality of the boiler meets the requirements.

6.Q: How to test the energy efficiency of boilers?

A: The boiler user shall conduct energy efficiency testing every two years, which shall be carried out in conjunction with the external inspection of the boiler and shall be carried out by an institution with appropriate qualifications. The test content includes the fuel consumption of the boiler, the outlet temperature and pressure of the medium, the boiler water supply and the feed water temperature and other key indicators.

7.Q: What should I do if the boiler has a low water level alarm?

A: When the boiler has a low water level alarm, the water level of the boiler should be checked immediately to confirm whether there is a lack of water. If there is a lack of water, water should be quickly replenished to the normal water level, and check the cause of the water shortage to prevent recurrence.

Send your message to this supplier